Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Arq. bras. med. vet. zootec. (Online) ; 72(4): 1137-1144, July-Aug. 2020. tab, ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1131517

ABSTRACT

Utilizaram-se quatro garanhões nos meses de janeiro, abril, julho e outubro de 2016, em dois protocolos, em que: GI (n=4; 5mL de solução salina, i.v.) e GII (n=4; 5000UI de hCG, i.v.) e subdividiram-se esses protocolos em ciclos (C1 e C2), seguindo o esquema crossover, sendo: CI=animais 1 (GI) e 2 (GII), avaliados nos dias D1, D3 e D5, e animais 3 (GI) e 4 (GII), em D2, D4 e D6; CII= animais 1 (GII) e 2 (GI), em D1, D3, D5, e animais 3 (GII) e 4 (GI), em D2, D4 e D6. Realizou-se o tratamento em D1 e D2 de cada ciclo e a ultrassonografia testicular no modo color Doppler e Doppler espectral, uma hora antes de cada coleta de sêmen e imediatamente após. Avaliou-se: número de reflexo de Flehmen, de montas sem ereção, início da monta, tempo de reação à ereção e total da monta e análises de qualidade seminal. Estatisticamente foram utilizados os testes de qui-quadrado e ANOVA. Não houve diferenças estatísticas (P>0,05) entre os parâmetros analisados. Concluiu-se que uma única dose de 5000UI de hCG em garanhões não causou alterações significativas nos parâmetros avaliados em diferentes estações do ano.(AU)


Four stallions were used in January, April, July and October 2016 in two protocols: GI (n=4; 5ml saline, iv) and GII (n=4; 5000 hCG, iv), and these protocols were subdivided into cycles (C1 and C2) following the cross over scheme, as follows: CI=animal 1 (GI) and 2 (GII) evaluated on days D1, D3 and D5 and animal 3 (GI) and 4 (GII) at D 2, D 4 and D 6; CII=animal 1 (GII) and 2 (GI) at D1, D3, D5 and animal 3 (GII) and 4 (GI) at D2, D4 and D6. Treatment was performed on D1 and D2 of each cycle and testicular ultrasound in color Doppler and spectral Doppler mode, one hour before each semen collection and immediately after. We evaluated: Flehmen's reflex number, mounts without erection, start of the mount, reaction time to erection and total mount and seminal quality analyzes. Statistically, the Chi-square and ANOVA tests were used. There were no statistical differences (P>0.05) between the analyzed parameters. It was concluded that a single dose of 5000IU hCG in stallions did not cause significant changes in the parameters evaluated in different seasons of the year.(AU)


Subject(s)
Animals , Male , Testis/diagnostic imaging , Chorionic Gonadotropin/administration & dosage , Horses/physiology , Seasons , Ultrasonography, Doppler, Color/veterinary
2.
Arq. bras. med. vet. zootec. (Online) ; 71(6): 1909-1916, Nov.-Dec. 2019. ilus
Article in English | LILACS, VETINDEX | ID: biblio-1055110

ABSTRACT

The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG's serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.(AU)


O estudo foi planejado para correlacionar exames ultrassonográficos e sorológicos realizados para o diagnóstico precoce (20 a 30d) de gestação. Cento e vinte (n= 120) receptoras bovinas foram sincronizadas (estro=D0), e embriões frescos produzidos in vitro foram transferidos em tempo fixo (TETF, D7). No experimento 1 (n= 46), o diagnóstico de gestação foi realizado no D20, pela detecção do fluxo sanguíneo do CL e pela sorologia de glicoproteínas associadas à gestação (PAGs). No experimento 2 (n= 30), a detecção da gestação foi realizada por meio da visualização do conteúdo do útero e também pela sorologia para PAGs. No experimento 3, a sorologia para PAGs foi realizada no D30. Em todos os experimentos, a visualização ultrassonográfica da vesícula e da viabilidade embrionária, realizada no D30, foi considerada padrão-ouro. O procedimento PROC FREQ testou o nível de concordância dos métodos diagnósticos. No D20, o diagnóstico baseado na vascularização do CL mostrou alta sensibilidade (100%) e apenas moderada especificidade (53,3%). Nesse mesmo dia, o diagnóstico sorológico não apresentou concordância (k=-0,08, P<0,46) com o padrão-ouro, além de baixa sensibilidade (6,3%). No entanto, a sensibilidade do exame sorológico aumentou drasticamente (6,3 para 100%) do D20 para o D25, contribuindo para detectar falsos negativos diagnosticados pela ultrassonografia, melhorando a acurácia (90 para 96,7%).(AU)


Subject(s)
Animals , Female , Pregnancy , Cattle , Pregnancy, Animal/blood , Serologic Tests/veterinary , Glycoproteins/analysis , Ultrasonography, Doppler, Color/veterinary , Embryo Transfer/veterinary
3.
Arq. bras. med. vet. zootec. (Online) ; 71(3): 863-868, May-June 2019. ilus
Article in English | VETINDEX, LILACS | ID: biblio-1011319

ABSTRACT

Portosystemic shunt (PSS) is an anomalous vascular connection between the portal venous system and the systemic circulation. These deviations connect the main portal vein (PV) or some portal branches to the vena cava (VC) or, less commonly, to the azygos vein (AV). The purpose of this case report was to describe the diagnosis of PSS in a dog classified as porto-azygos. This diagnosis is considered uncommon compared to other portosystemic shunts using ultrasonography and portography. The subject was a male dog, Yorkshire, 8 months old, presented neurological signs characterized by head press, ataxia, tremors and episodes of temporary blindness and deafness. Ultrasonographic examination revealed a dilated and curved anomalous vessel with approximately 0.6cm of diameter and turbulent flow seen through pulsed and color Doppler, and segmental dilation of the azygos vein. The portography revealed enhancement by iodinated contrast in the jejunal vein, the portal vein and an anomalous vessel flowing towards the azygos vein in the craniodorsal region of the abdomen. The PSS was surgically corrected with an ameroid constrictor. Ultrasonography and portography were effective at detecting and characterizing the portoazygos shunt despite some limitations.(AU)


Shunt portossistêmico (SPS) é uma comunicação vascular anômala entre o sistema venoso portal e a circulação sistêmica. Esses desvios comunicam a VP ou alguma de suas tributárias à veia cava ou, menos comumente, à veia ázigos (VA). O objetivo do presente estudo foi descrever o diagnóstico, por meio de ultrassonografia e portografia, de um caso de shunt extra-hepático em cão, classificado como portoázigos e considerado incomum quando comparado aos demais tipos de desvio portossistêmico. Um cão, macho, raça Yorkshire, oito meses de idade, chegou ao Hospital Veterinário da Universidade Federal de Minas Gerais apresentando sinais neurológicos, caracterizados por andar apoiando a cabeça na parede, ataxia, tremores, episódios de cegueira e surdez. Ao exame ultrassonográfico, observou-se vaso anômalo calibroso e tortuoso de aproximadamente 0,6cm de diâmetro e fluxo turbulento ao Doppler pulsado e colorido, bem como dilatação segmentar da VA. A portografia revelou realce de contraste iodado em veia jejunal, porta e vaso anômalo (shunt) seguindo em direção à VA em região dorsal do abdômen. Foi realizada a correção cirúrgica do SPS por meio de anel ameroide. A ultrassonografia e a portografia foram eficientes na detecção e caracterização do shunt portoázigos, mesmo que com algumas limitações.(AU)


Subject(s)
Animals , Male , Dogs , Portasystemic Shunt, Surgical/veterinary , Dog Diseases/diagnostic imaging , Portography/veterinary , Ultrasonography, Doppler, Color/veterinary
4.
Pesqui. vet. bras ; 38(3): 565-571, mar. 2018. ilus, tab
Article in English | LILACS, VETINDEX | ID: biblio-966942

ABSTRACT

B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies.


O exame ultrassonográfico modo-B é uma importante ferramenta diagnóstica que permite caracterizar a anatomia interna dos órgãos e, complementada pelo exame modo Doppler, possibilita realizar a avaliação hemodinâmica vascular, aumentando a acurácia diagnóstica. Desta forma, este trabalho teve como objetivo a caracterização ultrassonográfica e mensuração dos segmentos do bulbo ocular modo-B, assim como a avaliação da artéria oftálmica externa pelo Doppler colorido e pulsado. Foram avaliados 60 bulbos oculares de 30 cães de diferentes raças utilizando transdutor microconvexo de 8,5MHz. Inicialmente foi realizada biometria por meio do exame em modo-B dos seguintes seguimentos: comprimento axial (M1), profundidade da câmara anterior (M2), espessura da lente (M3), comprimento da lente (M4), profundidade da câmara vítrea (M5), comprimento do disco óptico (M6) e diâmetro do nervo óptico (M7). A artéria oftálmica externa foi identificada pelo Doppler colorido e seu fluxo foi avaliado por meio do Doppler pulsado, sendo mensurados: velocidade do pico sistólico (VPS), velocidade diastólica final (VDF), índice de resistividade (IR) e índice de pulsatilidade (IP). Não foi verificada diferença estatística para os valores biométricos dos seguimentos oculares entre os olhos direito e esquerdo (p>0,05). A profundidade da câmera vítrea (M5), mostrou-se a variável biométrica com maior simetria bilateral, variando entre 0,79 a 0,87cm e 0,78 a 0,86cm para o olho direito e esquerdo, respectivamente. A artéria oftálmica foi visibilizada sobre o nervo óptico em direção ao bulbo ocular, com fluxo marcado em vermelho. Não houve diferença estatística significativa entre os valores Dopplervelocimétricos da artéria oftálmica entre do olho direito e esquerdo dos animais avaliados (p>0.05). O índice de resistividade (IR) médio evidenciou valores médios sendo igual a 0,63±0,03, bilateralmente. A velocidade basal média foi 17,50cm/s e 18,18cm/s no pico sistólico e 6,21cm/s e 6,68cm/s no final da diástole, para os olhos direito e esquerdo, respectivamente. A caracterização anatômica, biométrica e hemodinâmica utilizando o exame ultrassonográfico modo-B e as modalidades do Doppler permitiram a avaliação ultrassonográfica e Dopplervelocimétrica dos componentes do bulbo ocular nos cães de diferentes raças, podendo ser utilizados na rotina clínica oftalmológica para identificação de patologias oculares.


Subject(s)
Animals , Dogs , Ultrasonography, Doppler, Color/veterinary , Diagnostic Techniques, Ophthalmological/veterinary , Hemodynamics , Dogs
5.
Arq. bras. med. vet. zootec. (Online) ; 69(5): 1089-1096, set.-out. 2017. ilus, tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-876985

ABSTRACT

Informações sobre a vascularização da parede folicular e do corpo lúteo equino, associadas à superovulação, são escassas. Com o objetivo de avaliar o efeito superovulatório do extrato de pituitária equina (EPE) no fluxo sanguíneo folicular e luteal, foram utilizadas seis éguas Puro Sangue Árabe, em dois ciclos estrais (controle e tratamento). As éguas foram monitoradas diariamente por ultrassonografia modo B, até que os folículos atingissem diâmetro de 23mm (desvio). No ciclo tratamento, as éguas receberam 8mg de EPE, uma vez ao dia, por via IM, até que dois ou mais folículos atingissem o diâmetro entre 32 e 35mm. A ovulação foi induzida com acetato de deslorelina, quando os folículos atingiram, no mínimo, 35mm. No momento do desvio folicular, da indução da ovulação e do último exame pré-ovulatório, foi utilizada a ultrassonografia modo B para medir o diâmetro dos folículos e, no oitavo dia pós-ovulação, para a área do corpo lúteo (CL). Utilizou-se também ultrassonografia com Doppler colorido para avaliar a perfusão sanguínea da parede folicular e do parênquima luteal. No ciclo controle, foi realizado o mesmo procedimento, exceto pelo uso do EPE. Os dados foram submetidos à análise de variância, com nível de significância de 5%. Não foi observado efeito do EPE sobre o número de ovulações, o diâmetro dos folículos, a vascularização da parede folicular e a concentração sérica de estrógeno. Os animais, tratados ou não, apresentaram CLs funcionais, não havendo diferença na área do parênquima ou da vascularização luteal, nem na concentração sérica de progesterona, no oitavo dia após a ovulação. Foi observado que o EPE proporcionou um maior número de folículos subordinados no momento da indução da ovulação do folículo dominante (P ≤ 0,05). Embora esses folículos não tenham chegado a ovular, concluiu-se que o EPE atuou no crescimento de folículos, que podem ser utilizados em outras biotécnicas, como a transferência de oócitos, com maior aproveitamento da reserva folicular de ovários equinos.(AU)


Knowledge about follicle and corpus luteum vascularization associated with superovulation in mares is scarce. Aiming to evaluate the effect of equine pituitary extract (EPE) on superovulation, the experiment was conducted using six mares Purebred Arabian in two estrous cycles (control and treatment). The mares were synchronized, and monitored daily by ultrasound B mode until the follicles reached diameter ≤ 23 mm (deviation). In the treatment cycle, from the deviation, mares received 8 mg of EPE, once a day, intramuscularly, until two or more follicles reached a diameter between 32 and 35 mm. Ovulation was induced with deslorelin acetate when follicles reached at least 35 mm. At the time of follicular deviation, induction of ovulation and final preovulatory exam, it was used B-mode ultrasound to measure the diameter of follicles and on the eighth day after ovulation to measure the area of the corpus luteum (CL); color Doppler was also used to assess blood perfusion of the follicle wall and luteal parenchyma. In the control cycle was performed the same procedure except for the use of EPE. Data were subjected to analysis of variance, with 5% significance level. There was no effect of EPE on ovulation number, diameter of follicles, vascularity of the follicular wall and serum estrogen concentration. The animals treated or not, showed functional CLs, with no difference in parenchymal area or luteal vascularization, or in serum progesterone concentration on the eighth day after ovulation. It was observed that the EPE provided a greater number of subordinate follicles at the time of induction of ovulation of the dominant follicle. Although these follicles have failed to ovulate, it was concluded that EPE influenced the follicles growth, and it can be used in other biotechnologies, with greater utilization of equine ovarian follicular reserve.(AU)


Subject(s)
Animals , Female , Corpus Luteum/blood supply , Corpus Luteum/diagnostic imaging , Horses/physiology , Ovarian Follicle/blood supply , Ovarian Follicle/diagnostic imaging , Regional Blood Flow/physiology , Superovulation , Ultrasonography, Doppler, Color/veterinary
6.
Arq. bras. med. vet. zootec ; 68(4): 907-912, jul.-ago. 2016. tab, graf, ilus
Article in English | LILACS, VETINDEX | ID: lil-792464

ABSTRACT

The aim of this study was to determine the vascular indices of adrenal blood flow in healthy dogs (systolic velocity - SV; diastolic velocity - DV; resistance index - RI). Eighteen dogs (thirty six adrenal) were studied. Physical examination, biochemical profile and dexamethasone suppression test were performed to determine general health status. Echotexture, size, contours and margins, and overall shape of the adrenal gland (right and left) were assessed via ultrasound. By spectral Doppler of the phrenic-abdominal artery, the SV, DV, and RI were acquired. Animals did not show alterations in clinical and laboratory examination and suppression of cortisol. Normal homogeneous and echotexture, regular contours and margins and normal shape and size were verified via B mode. Spectral Doppler of the phrenic-abdominal artery showed monophasic-patterned waves and low vascular resistance and systolic peak evident with means values: left adrenal - SV = 31.34cm/s, DV = 9.54cm/s and RI = 0.69; and right adrenal - SV = 27.83cm/s, DV = 7.71cm/s and RI = 0.68. Doppler evaluation of adrenal was easily implemented and may provide base line data in the study, allowing for the use of this technique as a diagnostic tool for diseases of the dog's adrenal.(AU)


Objetivou-se determinar os índices vasculares do fluxo sanguíneo das glândulas adrenais de cães saudáveis (velocidade sistólica - VS; velocidade diastólica - VD; o índice de resistência - IR). Foram utilizados neste estudo 18 cães (36 adrenais). Foram realizados exame físico, perfil bioquímico e teste de supressão com dexametasona para determinar o estado geral de saúde (higidez). Ecotextura, ecogenicidade, tamanho, contornos e margens e o formato das glândulas adrenais (direito e esquerdo) foram avaliados por meio da ultrassonografia convencional. Ao Doppler espectral da artéria frênico-abdominal, foram adquiridos a VS, a VD e o IR. Os animais não apresentaram alterações aos exames clínico, laboratorial e de supressão do cortisol. Ao exame ultrassonográfico, foram verificados ecotextura homogênea, ecogenicidade, formato e tamanhos normais, além de os contornos e as margens serem regulares. Ao Doppler espectral da artéria frênico-abdominal, verificaram-se ondas com padrão monofásico, com resistência vascular baixa e pico sistólico evidente, sendo os valores médios: adrenal esquerda - VS = 31,34cm/s, VD = 9,54cm/s e IR = 0,69; e adrenal direita - VS = 27,83cm/s, VD = 7,71cm/s e IR = 0,68. A avaliação Doppler das adrenais foi facilmente implementada e pode fornecer dados de referência, permitindo a utilização dessa técnica como uma ferramenta de diagnóstico para doenças das adrenais em cães.(AU)


Subject(s)
Animals , Dogs , Adrenal Glands/blood supply , Adrenal Glands/diagnostic imaging , Physiological Phenomena , Adrenal Glands/pathology , Aorta, Abdominal/diagnostic imaging , Ultrasonography, Doppler, Color/veterinary
7.
Pesqui. vet. bras ; 36(6): 545-550, jun. 2016. tab, ilus
Article in English | LILACS, VETINDEX | ID: lil-792609

ABSTRACT

There is no standardization in the literature of kidney length in sheep at different ages, as there are few studies about the access with the Doppler triplex ultrasound for the renal vascularization in this species. Eighty healthy sheep of three age groups of Ile de France and White Dorper breed were used: 20 lambs, 30 yearlings and 30 adults (8 rams and 22 ewes). Renal healthiness of the animals was confirmed by serum biochemical tests of urea and creatinine, and by observation of renal architecture with conventional ultrasound, besides measurement of vital parameters. A portable ultrasound (My LabTM30 Vet Gold Esaote®, Esaote Healthcare) device was used, with a convex transducer with 3.5MHz frequency. After identification of the kidneys in two-dimensional mode, the measurement of length in the sagittal section was performed in all sheep (n=80). Then color Doppler was activated for visualization of renal and interlobar arteries of the right kidney, and the resistivity index (RI) of the yearlings (n=30) and ewes (n=22) was measured. Biochemical tests remained within normal limits and renal architecture was preserved. The values ​​of the right and left renal length were different between the groups, increasing with age (4.34cm and 4.31cm in lambs; 6.08cm and 6.23cm in yearlings; 7.57cm and 7.37cm in adults, respectively). Median values of RI of the renal artery were statistically different (p<0.05) between the groups of yearlings (0.57) and ewes (0.52). The median RI of the interlobar artery was similar in yearlings (0.58) and ewes (0.54).(AU)


Não há na literatura padronização do comprimento renal de ovinos, em diferentes idades, assim como existem poucos trabalhos sobre a vascularização renal nesta espécie. Utilizaram-se no total 80 ovinos hígidos de três faixas etárias, das raças Ile de France e White Dorper: 20 cordeiros, 30 borregos e 30 adultos (8 carneiros e 22 ovelhas). A higidez renal dos animais foi comprovada por exames bioquímicos séricos de ureia e creatinina e pela observação da arquitetura renal. Utilizou-se aparelho de Ultrassom portátil (My LabTM30 Vet Gold Esaote®, Esaote Healthcare), com transdutor convexo de frequência de 3,5MHz. Após identificação dos rins no modo bidimensional, foi realizada a mensuração do comprimento no corte sagital em todos os ovinos. Em seguida, Doppler colorido foi ativado para visualização das artérias renal e interlobar do rim direito, e mensurou-se o índice de resistividade dos borregos (n=30) e ovelhas (n=22). Os exames bioquímicos permaneceram dentro da normalidade e a arquitetura renal estava preservada. Os valores do comprimento renal direito e esquerdo foram diferentes entre os grupos, sendo crescente conforme a idade (4,34 e 4,31 em cordeiros, 6,08 e 6,23 em borregos, 7,57 e 7,37 em adultos). As medianas do IR da artéria renal foi estatisticamente diferente (p<0,05) entre os grupos dos borregos (0,57) e ovelhas (0,52). A mediana do IR da artéria interlobar não apresentou diferença entre borregos (0,58) e ovelhas (0,54).(AU)


Subject(s)
Animals , Creatinine/blood , Kidney/anatomy & histology , Kidney/blood supply , Sheep/anatomy & histology , Urea/blood , Ultrasonography, Doppler, Color/veterinary
8.
Pesqui. vet. bras ; 35(11): 919-924, nov. 2015. graf
Article in Portuguese | LILACS | ID: lil-767758

ABSTRACT

A ultrassonografia é um método de imagem não invasivo e uma ferramenta importante para o diagnóstico de uma variedade de enfermidades de animais. Neste trabalho foi realizada a técnica de ultrassonografia transabdominal em cinco tamanduás-bandeira (Myrmecophaga tridactyla), dois machos e três fêmeas, pertencentes ao Zoológico da Universidade Federal de Mato Grosso e acompanhada a necrópsia de um animal morto de causas naturais. Os animais do zoológico foram anestesiados com Tiletamina e Zolazepam (Zoletil®) e mantidos em plano anestésico com Isofluorano. Foram realizadas varreduras com transdutor linear (LA332) multifrequencial de 3,0 a 11 MHz do fígado, vesícula biliar, estômago, baço, rins, bexiga e testículos. Os resultados obtidos mostram que existem semelhanças entre a arquitetura esplênica, a textura e ecogenicidade hepática, a posição e a aparência ultrassonográfica da vesícula biliar quando comparado com a dos caninos. Existem diferenças como localização renal, localização dos testículos, espessura da parede do estômago e presença de liquido livre anecóico entre o estômago, baço e rim esquerdo em todos os animais estudados...


Ultrasonography is a method of non-invasive imaging and an important tool for diagnosing a variety of animal diseases. In this paper the technique of transabdominal ultrasonography in five anteaters (Myrmecophaga tridactyla), two males and three females, belonging to the Federal University of Mato Grosso Zoo and a necropsy of an animal dead for natural cause were performed. The Zoo animals were anesthetized with tiletamine and zolazepan (Zoletil®) and maintained with isoflurane. Linear multifrequency transducer (LA 332) of the 3.0 to 11 MHz scans of the liver, gallbladder, stomach, spleen, kidneys, bladder and testes. There are similarities between the splenic architecture, the liver texture and echogenicity and the gallbladder ultrassonografic position and appearance when compared to the canines. Differences exist as renal and testes location, stomach wall thickness and presence of free anechoic fluid among the stomach, spleen and left kidney in all animals studied...


Subject(s)
Animals , Abdomen , Xenarthra/anatomy & histology , Ultrasonography, Doppler, Color/veterinary , Viscera
9.
Arq. bras. med. vet. zootec ; 67(3): 935-939, May-Jun/2015. ilus, tab
Article in English | LILACS | ID: lil-779234

ABSTRACT

Objetivou-se descrever a utilização das técnicas Doppler e elastografia ARFI (acoustic radiation force impulse) na avaliação de neoplasias mamárias de gatas, métodos ainda não utilizados para tal estudo em fêmeas felinas. Após a avaliação física e específica das neoplasias mamárias de duas gatas, foram realizadas as avaliações ultrassonográfica modo-B (ecogenicidade, ecotextura e margeamento), Doppler colorido (característica do fluxo sanguíneo) e espectral (velocidade sistólica/VS; diastólica/VD; e índice de resistência/IR) e a eslatografia ARFI qualitativa (escala de cores) e quantitativa (velocidade de cisalhamento) dos nódulos mamários, avaliando a aplicabilidade destas técnicas para determinar a malignidade dos tumores mamários. Após mastectomia e histopatologia foram diagnosticados: caso 1: carcinoma tubular; e caso 2: carcinoma mamário cribiforme. As características do modo-B foram similares para ambos os casos (heterogeneidade e margens regulares e não invasivas). Ao Doppler verificou-se presença de neovascularização e valores considerados elevados para os índices vasculares (quando comparado com tecidos benignos de outras espécies, como por exemplo caninos) (caso 1 - VS: 23,1cm/s, VD: 8,5cm/s e IR: 0,63; caso 2 - VS: 47,4 e 24,5cm/s; VD: 16,1 e 6,1cm/s e IR: 0,66 e 0,75); assim como os valores da velocidade de cisalhamento dos tecidos (caso 1: 4,07 m/s; caso 2: 4,54 e 6,85 m/s) na elastografia quantitativa; sendo que na avaliação qualitativa observou-se predominante rigidez e não deformidade tecidual, características que podem indicar a malignidade tecidual. Conclui-se que estas técnicas podem auxiliar no estudo de neoplasias mamárias em felinos, sugerindo a implementação destas técnicas de imagem para estudos de tumores mamários em felinos.


Subject(s)
Animals , Cats , Mammary Neoplasms, Animal/diagnosis , Mammary Neoplasms, Animal , Elasticity Imaging Techniques/veterinary , Ultrasonography, Doppler, Color/veterinary , Diagnostic Imaging/veterinary
10.
Arq. bras. med. vet. zootec ; 67(3): 655-663, May-Jun/2015. graf
Article in English | LILACS | ID: lil-753913

ABSTRACT

Intraoperative ultrasound (IOS) can provide details on various conditions of the spinal cord and vertebral canal. The aim of the present study was to evaluate the feasibility of using IOS in dogs undergoing spinal surgery and to describe the main findings. The vertebral canal of 21 dogs was examined with intraoperative ultrasonography: 13 underwent spinal surgery for removal of herniated intervertebral disc material, three for stabilization of vertebral fracture/luxation, two for removal of vertebral neoplasia, and three for cauda equina decompression. Particular attention was given to signs of cord compression. Intraoperative ultrasonography was feasible and useful in dogs undergoing surgery for spinal cord or cauda equina decompression and fracture stabilization. It was not paramount for locating the compression when this had been done via computed tomography (CT), but it showed alterations in spinal cord parenchyma not observed on CT and also confirmed adequate decompression of the spinal cord. The main advantages of intraoperative ultrasonography were estimation of vascularization and extent of spinal cord lesion. Most importantly, it allowed real time evaluation of the spinal cord and vertebral canal, which permits the modification of the surgical procedure.


A ultrassonografia intraoperatória pode fornecer detalhes sobre diversas condições da medula espinal e canal vertebral. O objetivo deste trabalho foi avaliar a viabilidade da utilização da ultrassonografia intraoperatória em cães submetidos à cirurgia espinomedular e descrever os principais achados. O canal vertebral de 21 cães foi examinado com ultrassonografia intraoperatória - 13 foram submetidos à cirurgia para remoção de material de disco herniado, três para estabilização de fratura/luxação vertebral, dois para remoção de neoplasia vertebral e três para descompressão de cauda equina. Atenção especial foi dada a sinais de compressão medular. A ultrassonografia intraoperatória foi viável e útil em cães submetidos a cirurgia para descompressão da medula espinal ou cauda equina e estabilização de fratura. Apesar de não ser indispensável para localização da compressão quando isso havia sido feito através de tomografia computadorizada (TC), demonstrou alterações no parênquima que não haviam sido observadas pela TC e confirmou a adequada descompressão da medula espinhal. As principais vantagens da ultrassonografia intraoperatória foram: estimar a vascularização e a extensão da lesão medular. Principalmente, permitiu uma avaliação em tempo real da medula espinal e do canal vertebral, o que permite modificação do procedimento cirúrgico.


Subject(s)
Animals , Dogs , Spinal Canal , Spinal Cord , Spinal Cord Injuries/veterinary , Ultrasonography, Interventional/veterinary , Decompression, Surgical/veterinary , Neurologic Examination/veterinary , Intraoperative Period , Ultrasonography, Doppler, Color/veterinary
11.
Pesqui. vet. bras ; 35(5): 470-476, May 2015. tab, ilus
Article in English | LILACS | ID: lil-759383

ABSTRACT

Two ultrasound based fertility prediction methods were tested prior to embryo transfer (ET) and artificial insemination (AI) in cattle. Female bovines were submitted to estrous synchronization prior to ET and AI. Animals were scanned immediately before ET and AI procedure to target follicle and corpus luteum (CL) size and vascularity. In addition, inseminated animals were also scanned eleven days after insemination to target CL size and vascularity. All data was compared with fertility by using gestational diagnosis 35 days after ovulation. Prior to ET, CL vascularity showed a positive correlation with fertility, and no pregnancy occurred in animals with less than 40% of CL vascularity. Prior to AI and also eleven days after AI, no relationship with fertility was seen in all parameters analyzed (follicle and CL size and vascularity), and contrary, cows with CL vascularity greater than 70% exhibit lower fertility. In inseminated animals, follicle size and vascularity was positive related with CL size and vascularity, as shown by the presence of greater CL size and vascularity originated from follicle with also greater size and vascularity. This is the first time that ultrasound based fertility prediction methods were tested prior to ET and AI and showed an application in ET, but not in AI programs. Further studies are needed including hormone profile evaluation to improve conclusion.


Duas técnicas de predição de fertilidade, baseadas em ultrassonografia, foram testadas no momento da transferência de embriões (TE) e inseminação artificial (IA) em bovinos. Fêmeas bovinas foram submetidas a protocolos de sincronização de estro para TE e IA. Os animais foram escaneados por ultrassonografia imediatamente antes do procedimento de TE e IA para identificar o tamanho e vascularização do folículo e corpo lúteo (CL). Além disso, os animais inseminados foram escaneados onze dias após a inseminação para identificar o tamanho e vascularização do CL. Todos os dados foram comparados com a fertilidade utilizando-se do diagnóstico gestacional 35 dias após a ovulação. No momento da TE, a vascularização do CL apresentou-se positivamente relacionada com a fertilidade, sendo que animais com menos de 40% de vascularização do CL não ficaram gestantes. No momento da IA, assim como onze dias após a IA, nenhuma relação foi encontrada entre fertilidade e os parâmetros analizados (tamanho e vascularização do folículo e CL), enquanto que contrariamente, houve uma queda na fertilidade em vacas com vascularização do CL acima de 70%. Nos animais inseminados, o tamanho e vascularização do folículo foi positivamente relacionado ao tamanho e vascularização do CL, demonstrado pela presença de um CL maior e mais vascularizado proveniente de um folículo maior e mais vascularizado. O presente estudo é o primeiro a mostrar métodos de predição de fertilidade baseados em ultrassonografia no momento da IA e TE, demonstrando uma aplicabilidade prática no momento da TE. Novos estudos são necessários para suportar os resultados mostrados, incluindo análises hormonais.


Subject(s)
Animals , Female , Cattle , Corpus Luteum , Fertilization in Vitro/methods , Fertilization in Vitro/veterinary , Insemination, Artificial/instrumentation , Insemination, Artificial/veterinary , Ultrasonography, Doppler, Color/methods , Ultrasonography, Doppler, Color/veterinary , Fertility , Ovarian Follicle/embryology , Ovarian Follicle , Pregnancy Rate , Pregnancy, Animal , Reproductive Physiological Phenomena , Embryo Transfer/statistics & numerical data , Embryo Transfer/methods , Embryo Transfer/veterinary
12.
Braz. j. vet. res. anim. sci ; 50(5): 384-395, 2013. ilus, tab, graf
Article in English | LILACS | ID: lil-789888

ABSTRACT

The testicular artery is responsible for the blood supply that reaches the testis and has great importance in heat radiation. Vascular changes in the testis may lead to damage in sperm production, reflected in sperm motility and morphology. The aim of the present study was to evaluate correlations between testicular vascularity and sperm characteristic. Eight adult Santa Ines rams showing different reproductive status were used. The testicular vascularity and sperm characteristics were evaluated fortnightly during 90 days. Color Doppler ultrasonography was used to evaluate the testicular hemodynamic. Resistance index (RI) and pulsatility index (PI) of the testicular artery were evaluated by spectral-Doppler mode. The color-Doppler mode was used to evaluate the blood flow of the pampiniform plexus and testicular parenchyma. The semen analyses assessed were volume, concentration, motility, and morphology. The data were submitted to Pearson´s linear correlations test (p 0.05 was considered significant). No correlations were found between motility and testicular hemodynamic. The percentage of total sperm defects was positively correlated to left and right parenchymal score and to left RI and PI. On the other hand, the pampiniform plexus score was positively correlated to the number of colored pixels and negatively correlated to the RI and PI, for both sides. This study showed that the increase of sperm defect can be related to increase of testicular blood flow; however, more studies are need.


A artéria testicular é responsável pelo fluxo de sangue que chega aos testículos e tem grande importância na termorregulação. Mudanças vasculares nos testículos podem levar à queda da produção espermática, refletindo na motilidade e morfologia. O objetivo deste trabalho foi avaliar as correlações entre a vascularização testicular e as características espermáticas. Foram utilizados oito carneiros adultos Santa Inês com diferentes status reprodutivos. A vascularização testicular e as características seminais foram avaliadas por um período de 90 dias. A ultrassonografia Doppler colorida foi utilizada para avaliar a hemodinâmica testicular. Foram calculados os índices de resistência (RI) e os índices de pulsatilidade (PI) com o modo espectral do Doppler. O modo colorido do Doppler foi utilizado para analisar o fluxo sanguíneo do plexo pampiniforme e do parênquima testicular. As características seminais avaliadas foram o volume, concentração, motilidade e morfologia. Os dados foram submetidos ao teste de correlação linear de Person (P 0.05 foi considerado significativo). Não foram encontradas relações entre motilidade e a hemodinâmica testicular. A porcentagem de defeitos totais correlacionou-se positivamente com o escore de vascularização dos parênquimas direito e esquerdo, e com o RI e PI esquerdos. Também o escore de vascularização dos plexos se correlacionou positivamente com a média de pixels e negativamente com o RI e PI, de ambos os lados. Este trabalho mostrou que o aumento de defeitos espermáticos pode estar correlacionado com o aumento do fluxo sanguíneo nos testículos; contudo, mais estudos são necessários.


Subject(s)
Animals , Hemodynamics , Sheep/physiology , Semen , Testis/physiology , Testis/blood supply , Sperm Motility , Ultrasonography, Doppler, Color/veterinary
13.
Journal of Veterinary Science ; : 67-71, 2012.
Article in English | WPRIM | ID: wpr-13090

ABSTRACT

The objective of this study was to investigate the effects of oxytocin infusion on corpus luteum (CL) function during early to mid-diestrus by measuring luteal size (LS) and luteal blood flow (LBF) along with plasma levels of progesterone (P4) and prostaglandin metabolites (13,14-dihydro-15-keto-prostaglandin F2alpha, PGFM). On day (D) 7 of the estrus cycle (D1 = ovulation), seven cows received 100 IU of oxytocin (OXY) or placebo (PL) following a Latin square design. LS and LBF increased in both groups over time and no differences were observed between the groups. PGFM did not differ either within the groups over time or between the groups at any time point. P4 of the OXY group was higher compared to that of the the PL group 360 min after the infusion (p = 0.01) and tended to be higher at the time points 450 min, 48 h, and 72 h (all p = 0.08). Results from this study support the hypothesis that OXY is not directly involved in the mechanism(s) governing blood flow of the CL and has no remarkable effects either on luteal size or P4 and PGFM plasma levels. Further investigation is needed to elucidate the role of OXY in CL blood flow during early and late luteal phases.


Subject(s)
Animals , Female , Cattle/physiology , Corpus Luteum/blood supply , Dinoprost/analogs & derivatives , Estrous Cycle/drug effects , Immunoenzyme Techniques/veterinary , Organ Size/physiology , Oxytocin/pharmacology , Progesterone/blood , Random Allocation , Ultrasonography, Doppler, Color/veterinary
14.
Journal of Veterinary Science ; : 155-159, 2010.
Article in English | WPRIM | ID: wpr-221267

ABSTRACT

Spectral waveform analysis of blood flow velocity in the major arteries of six healthy, conscious immature micropigs was determined using Doppler ultrasonography. Doppler spectral tracings were recorded from the external iliac artery, femoral artery, and renal arcuate artery. Tracings were also taken from three parts of the common carotid artery and two parts of the abdominal aorta. Spectral Doppler parameters included peak systolic velocity, early diastolic velocity, peak systolic velocity-to-end diastolic velocity ratio, resistive index, and pulsatility index. In addition, the diameter of major arteries and indirect blood pressure were measured. These results from spectral Doppler analysis in major arteries may be useful as reference ranges in the future studies of vascular hemodynamics in immature micropigs.


Subject(s)
Animals , Male , Arteries/physiology , Blood Flow Velocity/physiology , Swine , Swine, Miniature , Ultrasonography, Doppler, Color/veterinary
15.
Journal of Veterinary Science ; : 79-81, 2006.
Article in English | WPRIM | ID: wpr-228005

ABSTRACT

Renal ischemia as a course of renal transplantation is a common cause of renal dysfunction as renal failure. The purpose of this study was to investigate the influence of ascorbic acid on blood urea nitrogen (BUN), creatinine (Cr) and resistive index (RI) for dog models with renal ischemia-reperfusion (I/R) injury. Renal ischemia was induced on 6 Beagle dogs. The left kidney was exposed to normothermic ischemia for a short period at 30 min followed by reperfusion. On the blood Cr level and RI, there was no significant difference comparing both groups. 14 days after I/R injury a significant reduction on the blood BUN level was observed in the vehicle group (34.06 mg/dl) compared to that of ischemia induced treated group (10.3mg/dl) (p < 0.05). In conclusion, administration of ascorbic acid for renal ischemic-reperfusion injury had influence on blood BUN level, but it was not revealed the influence on blood Cr and RI.


Subject(s)
Animals , Dogs , Male , Antioxidants/pharmacology , Ascorbic Acid/pharmacology , Blood Urea Nitrogen , Creatinine/blood , Dog Diseases/blood , Kidney Diseases/blood , Random Allocation , Reperfusion Injury/blood , Ultrasonography, Doppler, Color/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL